Opened 14 years ago

Last modified 14 years ago

#35 accepted defect

Probar inversión de replicas del celerra en VNX

Reported by: tonin Owned by: tonin
Milestone: SANUCO 1.1 Component: NAS
Version: 1.0 Severity: block
Keywords: Cc:
Origen: Parent ID:

Description (last modified by tonin)

Configuramos replicas entre ambos sistemas para la migración, se realizan bien, pero el popup de propiedades desde el VNX5500 presenta errores y tras el failover, no podemos reanudar la replica ni desde el GUI ni desde línea de comandos.

Child Tickets

Change History (3)

comment:1 Changed 14 years ago by tonin

  • Description modified (diff)
  • Owner set to tonin
  • Status changed from new to accepted

No va bien.

comment:2 Changed 14 years ago by tonin

Desde comandos en las control station del NS y VNX, obtenemos tras el failover:

  • Desde el primer origen de la replica (ns40):

[nasadmin@cs_uco ~]$ nas_replicate -start limboftp-prueba-failover
Error 13160415661: The command was issued on the wrong side.

  • Desde el primer destino de la réplica, origen tras el failover (vmx5500):

[nasadmin@vnxcs ~]$ nas_replicate -start limboftp-prueba-failover
Error 13160415307: The object is not in right state for replication.

  • En el vnx si consultamos la información de la réplica, vemos que devuelve el error 26045317495 sobre el estado de la misma:

[nasadmin@vnxcs ~]$ nas_replicate -info limboftp-prueba-failover
ID = 337_CK200072200867_0000_151_CKM00110600602_2007
Name = limboftp-prueba-failover
Source Status = Info 26045317486: Failed Over
Network Status = OK
Destination Status = Info 26045317495: Replication session state is not accessible.
Last Sync Time =
Type = filesystem
Celerra Network Server = cs_uco
Dart Interconnect = vnxcs_cs_uco_nfs
Peer Dart Interconnect = cs_uco_vnxcs_nfs
Replication Role = source
Source Filesystem = limboftp
Source Data Mover = server_2
Source Interface = 150.214.110.204
Source Control Port = 0
Source Current Data Port = 0
Destination Filesystem = limboftp
Destination Data Mover = server_2
Destination Interface = 150.214.110.67
Destination Control Port = 0
Destination Data Port = 0
Max Out of Sync Time (minutes) = 5
Current Transfer Size (KB) = 0
Current Transfer Remain (KB) = 0
Estimated Completion Time =
Current Transfer is Full Copy = No
Current Transfer Rate (KB/s) = 0
Current Read Rate (KB/s) = 0
Current Write Rate (KB/s) = 0
Previous Transfer Rate (KB/s) = 0
Previous Read Rate (KB/

comment:3 Changed 14 years ago by tonin

Abro con EMC con esta información la incidencia http://powerlink.emc.com/mysupport/index.jsf?CASE_NUMBER=41056800

Note: See TracTickets for help on using tickets.